The shape of the oil tank truck is beautiful and the structural parts are all subjected to the sandblasting pretreatment process; the oil tank truck body is welded with a special tank tooling fixture, which is welded with the automatic protective welding machine; the painting is completely carried out according to the standard of the luxury passenger car painting process, so that the bodywork It has the same beautiful appearance as a passenger car, and its quality has reached the industry level.

CIMC Oil Tank Truck Safety Device

Explosion-proof: equipment Explosion-proof manhole can prevent leakage of the medium in the tank when the oil tank truck rllover .And it can release the gas once the oil tank truck has accident and on fire, efficiently prevent the oil tank truck from explosion. Chemical vehicle adopt large volume safety valve, can efficiently prevent the oil tank truck from explosion

Emergency shut-off valve(Pneumatic bottom valve): When there is am impact on the discharging pipe,the emergency shut-off valve will shut off to prevent massive leakage.

Breath valvethe breath valve of oil tank truck and chemical vehicle has function of preventing over flow, roll over and fire resistant, and when it oil tank truck body roll over,it can not leak the liquid

Top protect device:strong coaming board structure can protect the accessories on the top of the tank from impacting if there is a rollover.

Integral electrical system; adopt integrated wiring,connecting the light with water-proof clip upgrade the safety .

Precautions for safe transportation of oil tank trucks

Precautions for controlling combustibles

1. It is necessary to prevent oil spilling from the oil storage container of the tanker truck. The oil spills, spills, drips, leaks and spills that occur during the loading and unloading of oil products in tank trucks shall be promptly removed and dealt with.

2. It is strictly forbidden to pour oil dirt, oil sludge, waste oil, etc. into the sewer after unloading the cargo from the tanker, and should be collected and placed in the designated place for proper disposal.

3. All flammable materials should be removed near buildings such as oil tanks, warehouses, pump rooms, oil distribution rooms, and oil blending workshops.

4. The oil-soaked cotton yarn, oil rags, oil gloves, oil paper, etc. used in the maintenance and maintenance of the oil tank truck should be placed in a covered iron drum outside the workshop and removed in time.

Precautions for cutting off the source of fire

1. It is strictly forbidden to bring matches, lighters or other types of fire into the oil depot, oil product storage area, and oil product receiving and dispatching operation area. Strictly control the flow of fire sources and open flame operations.

2. Pyrotechnics are strictly prohibited in the oil depot, and when open flames must be used for repair operations, it must be reported to the relevant department for review and approval and safety precautions have been taken before the fire can start.

3. Before cars and tractors enter the warehouse, they must wear a fire shield at the exhaust pipe opening, and immediately turn off the engine after parking. It is strictly forbidden to inspect and repair the vehicle in the warehouse, and it is not allowed to start the engine during the operation.

4. When railway locomotives are put into storage, isolation vehicles must be attached, the ash box baffle shall be closed, and the furnace shall not be cleaned in the storage area or stay in the non-operation area.

5. The tanker said at the dock that the use of open flames is strictly prohibited. It is forbidden to carry fire sources on board.

Prevent electric sparks from causing combustion and explosion

1. All electrical equipment used in oil depots and all working places must be explosion-proof, and the installation must meet safety requirements. The wires must not be broken, exposed or short-circuited.

2. Over the oil depot, it is strictly forbidden to cross over high-voltage wires. The distance between the oil storage area and the barreled light oil warehouse and the wire must be more than 1.5 times the length of the electric pole.

3. The rails leading into the oil depot must be installed with insulating partitions before the entrance to prevent the external power source from flowing into the oil depot from the rails and sparking.

Prevent sparks caused by metal friction and cause combustion and explosion

1. Strictly implement the relevant regulations on warehouse entry and exit and operation area. It is forbidden to wear nail shoes or shoes with iron palms.Enter the oil depot, let alone climb oil tanks, tankers, tank trucks, tank cars and step on oil drums, andMule horses and iron wheels are prohibited from entering the reservoir area.

2. It is not allowed to use iron tools to knock out the lid of the container. When opening the vat lid and tanker lid, you should use a brass wrench or an alloy wrench that does not spark when colliding.

3. Avoid collision of metal containers with each other in the warehouse. Not to be able to roll on the concrete floor without a pad circle of oil drums.

4. During the loading and unloading operations of the oil products of the tanker truck, avoid the loading and unloading crane pipe being inserted and pulled out of the tank car port or Collision during tanker hatch. Wherever there is oil and gas, iron metals should not be hit.

Prevent the accumulation of oil vapor and cause combustion and explosion

1. Repair and welding of unwashed oil drums, oil tanks, oil tanks and other storage containers is strictly prohibited. After washing the container, open the lid to ventilate before preparing for welding. If necessary, perform visual explosion first.

2. The barreled light oil products stored in the warehouse should be checked frequently, and the leakage should be found to be replaced in time. The warehouses, cargo sheds, and receiving and dispatching rooms for barrels of light oil should maintain air flow.

3. In underground and cave oil tank areas, strictly prevent oil leakage. Ventilation equipment must be installed to maintain good ventilation to avoid accumulation of oil and gas.

Transportation collision and leakage prevention

1. Try to arrange the external interface of the tank body at the head part at both ends of the cylinder body because this part is not easy to be impacted;

2. The valve should be built-in as far as possible to reduce the part of the valve protruding to reduce or avoid impact;

3. The part of the tanker valve extending out of the cylinder must have a guardrail with sufficient strength to protect the valve from impact;

4. Install leak alarms at the more concentrated parts of the inlet and outlet valves for tankers containing high and extremely hazardous toxic media;

5. Emergency plugging devices should be added to tank trucks containing high and extremely hazardous toxic media, and emergency plugging measures can also be taken in case of toxic media leaks.

Why Choose Cimc Oil Tank Truck

First, the production experience of large-scale special vehicles for many years.

CIMC Linyu brand is a well-known domestic special vehicle manufacturer, especially in the production of large-scale special vehicles, with many years of production experience. Therefore, the high quality presented by CIMC Linyu tanker is worthy of recognition by consumers, and can truly meet the needs of the purchase of CIMC Linyu tanker, especially in the improvement of hardware facilities and equipment, relying on stable CIMC The tanker is able to ensure its effectiveness.

Second, customized production, can provide protection for targeted use needs

Combining its own years of experience in the production of special-purpose vehicles, CIMC oil tank trucks can also meet the customization needs to a certain extent, and can be designed according to the requirements of transportation, which is very good to some extent. Satisfying the implementation of high-standard requirements for capital accounting and regional transportation requirements is one of the most important factors for achieving targeted satisfaction, and better enhances the credibility of CIMC Linyu oil tank truck cooperation.

Third, the standardization of the implementation of the overall service

CIMC Linyu’s requirements for service and high, can be well carried out according to the agreement, and the market service reputation is excellent.
Which also provides a certain degree of support for the establishment of CIMC Linyu oil tank truck trust. The necessary protection.

Oil Tank Truck Specifications

Model CLY9408GRYF CLY9408GRYK CLY9340GRY CLY9401GSY
Tank volume 42m3 48m3 36m3 40m3
Dimensions 12850*2500*3900mm 12600/12800*2500*3800/3950mm 10600*2500*3700mm 11000*2500*3850mm
Rated contained mass 33000kg 33000kg 25500kg 31500kg
Wheelbase 7200+1350+1350 7200+1350+1350 6550+1310 5600+1310+1310
After hanging 1345mm 1420mm 1140mm 1230mm
Departure angle 21 19 28.5 27
Total mass 40000kg 40000kg 34450kg 39980kg
Curb quality 7000kg 7000kg 8950kg 8480kg
Remarks Single tire, straight can Round, variable cross section Reducing Reducing

Daily maintenance of oil tank truck

heng

1. The driving part that carries the oil tank is generally called the car chassis. Drivers are generally more proficient in this area. The problem is that after the tank truck is equipped with an oil pump, we install a drive shaft and a power take-off from the engine. With these two devices, we need to pay special attention to the operation, and the operation is improper. The device is scrapped.

2. The use and maintenance of the oil pump must be carried out in strict accordance with its operation and maintenance instructions, which are provided with the vehicle.

3. The use and maintenance of the fuel dispenser must be carried out strictly in accordance with its instruction manual, which is provided with the vehicle.

4. The oil output is slow, and no oil can be output. Please check the safety valve and filter net. These should be checked and cleaned frequently.

5. Oil tanks and piping systems should be cleaned regularly. Regularly check whether the joints of the piping system are well connected and the sealing is reliable.

6. In order to ensure the cleanliness of the oil tank, the oil tank and the oil delivery system should be cleaned regularly, and the internal and external joints at both ends of the oil delivery hose should be frequently coated with lubricating oil, which is easy and convenient for disassembly and assembly. After each work of the oil pipe, the inlet and outlet outer end caps (blocking caps) and both ends of the oil pipeline (blocking caps) should be covered in time to ensure the cleanliness of the pipe.

7. The oil load should not exceed the rated load quality.

8. The medium that the ball valve passes through should not be too dirty to protect the sealing ring and increase the service life of the ball valve. The ball valve should not work in a half-closed and half-open state for a long time, otherwise the sealing ring will be easily deteriorated. The handle of each ball valve should be in the driving Disabled.

9. The inlet pump network should be removed and washed frequently to prevent the oil residue from clogging the filter screen and affecting the flow rate.

10. Keep the breathing valve clean and keep it in working condition. The spring in the valve should not be replaced at will, so as not to affect the effect of inhalation and deflation. When the breathing valve is blocked, there is a danger of deformation of the tank.

11. In order to prevent fire accidents from oil trucks, it is not allowed to hit the parts on the oil truck with metal objects when the exhaust pipe, the muffler are damaged, the pipeline is leaking, or the conductive electrode is broken or broken, so as to avoid sparks and the oil truck. Fire-fighting equipment should be ready at all times.

12. If the sedimentation tank under the oil tank is frozen, it should not be baked by fire. It can be melted by hot steam or by driving the car into the greenhouse to defrost.

13. Before the operation of the refueling truck, the electric pole must be used to insert it into the wet ground, the grounding tape should be grounded, and the static electricity should always be maintained during the operation.

14. Check the fire extinguisher device before leaving the vehicle. The user of the refueling truck should be familiar with the use of the fire extinguisher, and perform inspection and maintenance according to its instructions.

15. Before the operation of the oil tanker, check whether the pipeline system is leaking, whether the grounding wire is disconnected, and whether the exhaust pipe is damaged. If the problem is found, it should be solved before the operation.

16. When measuring oil, it should be carried out in accordance with relevant regulations. In winter, if there is water in the self-priming pump, the water must be drained to prevent freezing and breaking the pump body.

17. When it is necessary to enter the oil tank to work, it should be well ventilated and there must be someone outside the tank to protect it. If necessary, clean the tank with soap and water before proceeding